The importance of supervised monitoring modules utilized in management and monitoring of extinguishing techniques

In many locations from chemistry laboratories to industrial facilities, in order to guarantee the safety of life and property in opposition to a potential fireplace hazard, extinguishing systems are used along with detection and alarm systems. It is also extraordinarily essential that the extinguishing methods put in could be triggered by the fireplace extinguishing management panel, in order to get rid of a potential fire with early intervention.
In order to fulfill these needs, and with 35 years of sectoral knowledge and experience, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel working according to the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the remote efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing process to be started manually and remotely; and
to guarantee that the extinguishing course of can be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these devices are produced using surface-mount expertise and are aimed toward making the automation of the extinguishing system and fireplace and gas detection system perfect.
Image copyright: Mavili
Mavili Elektronik develops its products by at all times considering the needs of the set up. In pressure gauge 0 10 bar ราคา that require the integration of the extinguishing system with the intelligent addressable fire detection system, it provides options by way of the monitoring modules that even have a ‘supervised’ possibility.
Supervised monitoring modules play an important function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a potential open or short circuit within the wiring between the contact monitoring modules and the peripheral methods could cause disruption of the triggering, with doubtlessly critical penalties. For this reason, when selecting monitoring modules, it should be taken under consideration that they’ve supervised features.
Image copyright: Mavili
Since Maxlogic clever addressable fire detection and alarm control panels are constantly speaking with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to monitor situations similar to open circuits and brief circuits that will happen in the system. Many duties may be carried out in the fireplace extinguishing set up, such as the management and monitoring of all valves that can interrupt the move of water, water circulate alarm switches, strain change, and electrical or diesel hearth pumps.
By adding two contact monitoring modules to two separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to manage errors and the opposite to manage the fireplace scenario, monitoring and control of the extinguishing system by way of an clever addressable fire detection and alarm system may be performed effectively.
For more information, go to www.mavili.com.tr/en